It has been a long couple of months but at last my EV is back up and running, this time with and HVC/LVC harness in place!
LVC is already wired in line with the throttle albeit to only the 2 rear battery boxes I will be wiring the 3rd and final (for now) battery box in tonight which will give me a proper low voltage cut out at 3.0v on the nose on any of the cells in any of the 3 battery boxes, basically if any of the cells hits 3.0v the throttle is cut, I have not tested this in place as yet but I have tested the board on the bench with a variable PSU as a test cell and sure enough the LVC “Sig” line drops to 0v when the cell pin goes below 3.0v.
Once the HVC/LVC loom is complete (Tonight) I will be wiring the HVC side of it into the BMS pin on the charger in an attempt to get the HVC working as well although this would only cut out as a last ditch safety measure as it cuts at 4.4v not 4.2v.
So I still need to upgrade the firmware on my charger to allow a CV cut out of 4.2v (currently limited to 3.99v) and also to put in some physical isolation of the chargers case from the chassis of the car, this is because when the charger is plugged in and running the chassis has some voltage on it, I would not call it live but I think the stray voltage might be either leakage from the bridge rectifier, or possibly inducted from the large toroid.
I also need to investigate a low voltage safety in the charger software as according to Steve the charger should error if it detects an abnormally low voltage and cause you to check to see if any dead cells are present, charging dead cells could result in a thermal runaway event (Yeah don’t I know it!)
And to top this lot I still need to implement the fuel gauge and the heater/demister.
Thursday, 22 May 2014
BC168 balance charger wigs out!
In order for me to test and balance all of the 108+ cell packs that I have discharged, graphed, charged and balanced over the last 2 months I needed to buy a good LIPO charger and Steve recommended the BC168 LIPO Fast charger/balancer for around £90, I looked it up online and sure enough it appeared to be the bees knees of LIPO chargers (and I still think it is) after running around 80 cell packs through it (not many according to Steve he has put several thousand through his) the ground connection wire to the breakout board was showing a significant browning of the plastic suggesting it was getting hotter than it should have, I did not consider this a major issue and carried on testing the remaining cell packs whilst angling the output fan over the breakout board to keep it from getting worse, however after only a few more cells the device began playing up and would not show a reading on and cell pack on S1 line, I initially suspected the breakout board but after testing this it turned out to be the device itself and now it won’t charge properly at all the voltage sensing seems to have gone out the window as it jumps wildly about trying to sense the correct voltage, basically it’s fried. Shit!
Not convinced I did anything wrong to damage the unit so we are going to try and get an RMA on it however as it is a fairly cheap device and they come from Hong Kong it may take more time than it is worth, for now Steve has lent me his so I can at least finish the remaining packs to get my car back on the road.
Not convinced I did anything wrong to damage the unit so we are going to try and get an RMA on it however as it is a fairly cheap device and they come from Hong Kong it may take more time than it is worth, for now Steve has lent me his so I can at least finish the remaining packs to get my car back on the road.
Collected 42 new (used) batteries
I collected my new batteries, They are used identical Turnigy LIPO’s 5S1P’s from Steve’s Electric MX5 which he is sadly breaking (house purchase forces cashing in of assets me thinks) still I intend to purchase the Motor and Controller from it to convert my RX8 so it is not all bad news.
Carried on testing the new cells same as before
1) Charge to 4.2v
2) Discharge and graph
3) Check graphs and discard any bad one’s (Steve assured me there should be none)
4) Balance good cell packs to 3.8v and fit them in 3rd and last battery box
Unfortunately when we pulled the batteries from Steve’s car we noticed an imbalance on some of the cells in a parallel block so all of them were showing cell 2 as being down at 1.5v and after testing and graphing these cells 8 of them showed an imbalance after a single charge and discharge and graph, and the failed one was done at 0.8v on cell 2.
I pulled these 8 to one side and collected another 6 from Steve to cover any possible bad ones (only needed 6 as Steve had given me 2 extra to cover the potential bad one in the first place, And as I completely forgot to take the bad ones back to him when I collected I now have all of these extra ones to find 6 good cells from to fill the last 6 slots in my last battery box (getting close now)
Last night (24th April) I fitted all the cells in the last 3rd battery box and packed them ready for wiring, just need to charge/graph and balance 6 more of the 14 cell packs I have and fit them before I can wire up the last box and close the lid.
As soon as this is done I will drop the remaining 8 iffy cells back to Steve, There is really only 1 definite bad cell in this 8 but I want to make sure the 6 I fit are all good and well balanced cell packs, after all I have just spent 2 months testing every single cell and balancing them perfectly.
Carried on testing the new cells same as before
1) Charge to 4.2v
2) Discharge and graph
3) Check graphs and discard any bad one’s (Steve assured me there should be none)
4) Balance good cell packs to 3.8v and fit them in 3rd and last battery box
Unfortunately when we pulled the batteries from Steve’s car we noticed an imbalance on some of the cells in a parallel block so all of them were showing cell 2 as being down at 1.5v and after testing and graphing these cells 8 of them showed an imbalance after a single charge and discharge and graph, and the failed one was done at 0.8v on cell 2.
I pulled these 8 to one side and collected another 6 from Steve to cover any possible bad ones (only needed 6 as Steve had given me 2 extra to cover the potential bad one in the first place, And as I completely forgot to take the bad ones back to him when I collected I now have all of these extra ones to find 6 good cells from to fill the last 6 slots in my last battery box (getting close now)
Last night (24th April) I fitted all the cells in the last 3rd battery box and packed them ready for wiring, just need to charge/graph and balance 6 more of the 14 cell packs I have and fit them before I can wire up the last box and close the lid.
As soon as this is done I will drop the remaining 8 iffy cells back to Steve, There is really only 1 definite bad cell in this 8 but I want to make sure the 6 I fit are all good and well balanced cell packs, after all I have just spent 2 months testing every single cell and balancing them perfectly.
Battery rebuild begins (12th April 2014)
Started by taking all the good batteries and stuffing them back in the boxes completed one box I am 6 cells short to complete the second (although these 6 failed cell packs are no good for an EV battery they are still useable for other projects) advised Steve of the additional battery requirements (he already knew about the 36 incinerated + 1 swollen cell pack, so 5 more required.)
As I could do no more battery stuffing I moved on to fitting the buss bars back in and realised I was going to need more (new) neoprene so I put in a web order for another roll.
At this point I decided to call it a day (weekend) and spend the rest of my spare time with the partner & kids (mowing and strimming the lawn more like!)
As I could do no more battery stuffing I moved on to fitting the buss bars back in and realised I was going to need more (new) neoprene so I put in a web order for another roll.
At this point I decided to call it a day (weekend) and spend the rest of my spare time with the partner & kids (mowing and strimming the lawn more like!)
Battery Testing Finally Completed (12th April 2014)
And by completed I mean:-
1) Ran every one of 72 x 5S1P cell packs through a discharge (to 3.5v) and graph test using the Powerlab8 Battery Workstation
2) Checked all the graphs to see if any cell packs were out of balance, made a note of the ones that were for additional test
3) Bottom balanced all Cell packs to 3.8v (Storage charge)
4) Checked all cell packs physically for any signs of swelling, (Weirdly every single one looked fine until the very last discharge test on the very last cell pack which swelled up like a balloon)
5) Ran all cell packs that failed first test through a balance charge (to 4.2v) using a BC 108 balance charger
6) Ran all cell packs that failed first test through a second discharge (to 3.5v) and graph test using Powerlab 8
7) Checked all graphs to see if any cell packs were still out of balance, Discarded any cell packs that were (5 were!)
All that lot basically took me 6 weeks of spare evenings to complete!
1) Ran every one of 72 x 5S1P cell packs through a discharge (to 3.5v) and graph test using the Powerlab8 Battery Workstation
2) Checked all the graphs to see if any cell packs were out of balance, made a note of the ones that were for additional test
3) Bottom balanced all Cell packs to 3.8v (Storage charge)
4) Checked all cell packs physically for any signs of swelling, (Weirdly every single one looked fine until the very last discharge test on the very last cell pack which swelled up like a balloon)
5) Ran all cell packs that failed first test through a balance charge (to 4.2v) using a BC 108 balance charger
6) Ran all cell packs that failed first test through a second discharge (to 3.5v) and graph test using Powerlab 8
7) Checked all graphs to see if any cell packs were still out of balance, Discarded any cell packs that were (5 were!)
All that lot basically took me 6 weeks of spare evenings to complete!
Battery Testing Continued
I spent several evenings this week (17th-23rd March 2014) testing batteries and have completed the first battery box 36 cell packs and the first few cell packs in the second (last remaining) battery box, so I probably have about 30 left to test, once this is done I can get onto the balancing, so far I have only had one cell pack show any signs of swelling and strangely this one seemed perfectly balanced, however Steve has recommended that I discard any that show signs of swelling, So I guess I will repurpose this one for another small battery powered project such as a 3D printed quad copter or the inverted pendulum balancing bot I am planning to build.
Let’s hope I don’t have many more that I will need to discard, I should be able to complete all this testing this weekend coming.
Let’s hope I don’t have many more that I will need to discard, I should be able to complete all this testing this weekend coming.
Battery testing begins
I began by removing the 2 remaining battery boxes that survived and getting them into my workshop, removed the lid from the first and removed all the buss-bars, LVC/HVC boards and all additional cabling until I had just the cells, attempted to pull one out, not budging, panicking a little as I was assuming they had all swollen due to the over charge I contacted Steve and asked how much force I could use on the banana leads after all I don’t want to start another fire in this box whilst I am trying to disassemble!
Steve was also assuming the batteries were probably swollen beyond use and this is the main reason I needed to get the whole lot apart to check for swelling and discard any swollen cells, after Steve’s reassurance that I could safely give them a good yank without puling the banana leads out of the cell packs, I went back for another try, this time I turned the whole box upside down and gave the end/edge of it a good whack on the bench in my workshop, flipped it back over and almost in despair grabbed a couple of banana leads and yanked!
To my surprise it popped out sweet as a nut, and of course once one was out the rest came easily, and to my great surprise and relief there was not a jot of swelling to be seen on any of them in fact they all looked good as new!
Borrowed a Powerlab8 from Steve and began testing batteries this weekend just gone 15th March. The powerlab8 is a cool little unit and does a lot of stuff but I was basically just using it to do a discharge from the overcharged state to an “Empty” state 3.5v whilst graphing the discharge on a PC that way you can see if any of the cells are out of balance or damaged in any way.
To achieve this is a little tricky though, the powerlab8 is best run from a 12v or 24v lead acid battery this allows you to do a fast charge/discharge at 20A, simulating actual usage discharge speeds, as I was not versed in the use of the powerlab8 Steve ran me through the basics via email, and after doing 4 discharges my 12V Lead acid battery hit its fully charged state (denoted by the voltage popping up to 14v, peukert effect!
As Steve explained) despite me attaching (what I thought were headlight) bulbs to the 12v to drain excess current, so after a little more fiddling around finding 12v devices that I could attach to drain the 12v and provide a load, I finally settled on the 4 bulbs I had initially, plus a 12v cooler box, plus a 12v car tyre pump, plus a single true headlight bulb wired so that it was on full beam i.e. both filaments lit, And at last this seemed to be enough, I was now able to continue testing and to my surprise at 4 x the speed as before for the first 4 tests I had only been dumping 5A rather than the 20A I had set because the 12v battery could not take any more.
So this greatly increased the speed at which I could test and by Sunday evening I had tested almost all of a single box worth of 5S1P cell packs, I think around 6 will need rebalancing for sure but I may just balance the whole lot and retest the ones that were out of balance to check there is no intrinsic issues.
This Still leaves me short the 36 cell pack’s I incinerated and 4 new LVC.HVC cut-off boards with extender boards (I had better make sure I use them this time eh! You f##!ng TWAT!)
And I am going to need to do some reworking of the buss-bars as well!
Steve was also assuming the batteries were probably swollen beyond use and this is the main reason I needed to get the whole lot apart to check for swelling and discard any swollen cells, after Steve’s reassurance that I could safely give them a good yank without puling the banana leads out of the cell packs, I went back for another try, this time I turned the whole box upside down and gave the end/edge of it a good whack on the bench in my workshop, flipped it back over and almost in despair grabbed a couple of banana leads and yanked!
To my surprise it popped out sweet as a nut, and of course once one was out the rest came easily, and to my great surprise and relief there was not a jot of swelling to be seen on any of them in fact they all looked good as new!
Borrowed a Powerlab8 from Steve and began testing batteries this weekend just gone 15th March. The powerlab8 is a cool little unit and does a lot of stuff but I was basically just using it to do a discharge from the overcharged state to an “Empty” state 3.5v whilst graphing the discharge on a PC that way you can see if any of the cells are out of balance or damaged in any way.
To achieve this is a little tricky though, the powerlab8 is best run from a 12v or 24v lead acid battery this allows you to do a fast charge/discharge at 20A, simulating actual usage discharge speeds, as I was not versed in the use of the powerlab8 Steve ran me through the basics via email, and after doing 4 discharges my 12V Lead acid battery hit its fully charged state (denoted by the voltage popping up to 14v, peukert effect!
As Steve explained) despite me attaching (what I thought were headlight) bulbs to the 12v to drain excess current, so after a little more fiddling around finding 12v devices that I could attach to drain the 12v and provide a load, I finally settled on the 4 bulbs I had initially, plus a 12v cooler box, plus a 12v car tyre pump, plus a single true headlight bulb wired so that it was on full beam i.e. both filaments lit, And at last this seemed to be enough, I was now able to continue testing and to my surprise at 4 x the speed as before for the first 4 tests I had only been dumping 5A rather than the 20A I had set because the 12v battery could not take any more.
So this greatly increased the speed at which I could test and by Sunday evening I had tested almost all of a single box worth of 5S1P cell packs, I think around 6 will need rebalancing for sure but I may just balance the whole lot and retest the ones that were out of balance to check there is no intrinsic issues.
This Still leaves me short the 36 cell pack’s I incinerated and 4 new LVC.HVC cut-off boards with extender boards (I had better make sure I use them this time eh! You f##!ng TWAT!)
And I am going to need to do some reworking of the buss-bars as well!